Cisco Flexible Solutions Taps Installation Guide
Description of the Taps and Passives
The following table lists the function of each port for each type of passive.
Passive
Function
Directional coupler
Port 1 = In
Port 2 = Out
Port 3 = Tap
Port 4 = not used
2-way splitter
Port 1 = In
Port 2 = Out 1
Port 3 = Out 2
Port 4 = not used
3-way balanced splitter
Port 1 = In
Port 2 = Out 1
Port 3 = Out 2
Port 4 = Out 3
3-way unbalanced splitter
Port 1 = In
Port 2 = High Out
Port 3 = Low Out 1
Port 4 = Low Out 2
Power inserter
Port 1 = RF/AC
Port 2 = RF/AC
Port 3 = AC input
Port 4 = not used
Required Installation Accessories
One coaxial cable-to-housing connector is required for each feeder port connection.
A housing-to-housing connector may be required to connect the tap or passive
directly to the input or output of another device. When taps that are not
self-terminating are used for end-of-feeder line, one 75 Ω line terminator is required
to terminate the feeder line at the output port.
OL-31976-01