Installing the Tap/Passive on a Strand 
 
5.  Thread the prepared KS-connectors into the housing at the cable side entry port 
locations as shown in the figure above. Make sure to tighten the connector 
according to the manufacturer’s recommended torque specification, typically 15 
ft-lb to 25 ft-lb (20.3 Nm to 33.9 Nm), but not to exceed 60 ft-lb (81.3 Nm). 
6.  Using a 3/16-in. hex-head driver or 3/16-in. straight blade screwdriver, tighten 
the two seizure screws from 15 in-lb to 20 in-lb (1.7 Nm to 2.3 Nm). See the 
diagram in step 5 for the location of the two seizure screws. 
7.  Replace the end plugs on the unused entry ports and torque with a 3/8-in. hex 
wrench from 30 in-lb to 50 in-lb (3.4 Nm to 5.6 Nm). 
8.  Attach the drop cable (RG-6 or RG-59) to the tap faceplate. 
Important: For any drop cables that will have AC power activated, be sure that 
power blocking device(s) are installed at the home to prevent AC from passing 
to subscriber televisions, set-top converters, or FM receivers. AC power must 
only be allowed to pass to the telephony equipment requiring it. 
 
Note: Be sure to provide strain relief for the coax drop cable per manufacturer’s 
recommendation, and terminate all unused F-ports with 75 Ω terminators. 
 
 