Cisco Cisco Surge-Gap Passives Installation Guide

Page of 8
78-567635-01 Rev C 
 
 
 
Installing the PDU 
 
Installing the PDU 
About the PDU 
The Multimedia Tap system is designed to allow a two step upgrade process for 
power passing capability.  During the initial network construction, Multimedia Taps 
are installed to provide CATV and other non-power passing subscriber services. 
As hybrid fiber-coax (HFC) telephony is rolled out into the service area, the PDU is 
installed to provide power passing capability for the Multimedia Tap system.  The 
PDU is located or “sandwiched” between the tap housing and the tap faceplate.  The 
same PDU is installed regardless of the tap faceplate attenuation characteristics. 
Reference 
Refer to Multimedia Tap System Installation and Operation Guide, part number 562375, 
for complete installation instructions for the Multimedia Tap and PDU. This 
document can be ordered from your representative. 
Required tools 
Make sure you have the following tools before proceeding. 
 
#1 Phillips-head screwdriver 
 
Socket wrench with 3/8-in. hex socket 
 
9/64-in. Allen-head driver 
Before you start 
Before you start, inspect the label on the tap housing (see the following diagram) to 
find the part number. 
 
 
If the six-digit part number ends with “A,” proceed to “Installation procedure.” 
 
If the part number ends with any other letter, use the procedure in the manual 
and disregard the “Installation procedure.”