Cisco Headend System Release 2.5

Page of 79
 
3-10 
Enabling CVT Downloads on the DNCS 
738185 Rev B 
Gather Required Information for the osmAutoMux.cfg File,
 Continued 
Complete these steps to find and record the output TSID information required for 
the osmAutoMux.cfg file. 
1. 
From the DNCS Administrative Console, click the Element Provisioning tab. 
2. 
Click QAM. The QAM List window opens. 
3. 
Using the information in the QAM List window, record the name and the 
output TSID for each of the following QAM types in the order presented. 
• 
Primary (local) BFS QAM for the primary headend 
• 
Video QAMs for the primary headend 
• 
Secondary BFS QAM for the secondary headend 
• 
Video QAMs for the secondary headend 
• 
(if applicable) BFS QAM for an additional headend 
• 
(if applicable) video QAMs for an additional headend 
Important:  You may have multiple rows for each output on a BFS QAM. For 
example, if you are using and MQAM as a BFS QAM, the QAM List window 
contains a separate row for each output on the MQAM. Record the output 
TSID for each output on the MQAM (4 outputs). 
4. 
If you have additional headends, continue the same pattern described in step 
3 to record the QAM Name and Output TSID for the BFS QAM and all video 
QAMs for each headend. 
5. 
When you have finished recording the output TSIDs for the BFS QAMs and 
video QAMs in each headend, select File and choose Close to close the QAM 
List window. 
 
Obtaining Headend IDs 
Complete these steps to obtain headend IDs. For the primary BFS QAM in the 
primary headend, you must query the database for the real headend ID. For your 
other headends, use an artitray but unique number for each headend ID. 
1. 
From an xterm window, log on to the DNCS as root. 
2. 
Type the following command and press Enter
dbaccess dncsdb – 
Result:  
The message Database selected appears. 
 
Continued on next page