Cisco Cisco Digital Service Access Node (DSAN) 8210 Installation Guide
Attaching the Coaxial Connectors
78-4041038-01 Rev B
45
Attaching the Coaxial Connectors
The DSAN requires pin-type connectors for all RF connections.
Important: Standard pin connectors, with pins extending 1.5 to 1.6 in. (3.8 to 4.1 cm)
from the shoulder, require no trimming. You must trim longer pins before inserting
them into the housing.
from the shoulder, require no trimming. You must trim longer pins before inserting
them into the housing.
To Connect the Coaxial Cable Pin Connector
Complete the following steps for each coaxial pin connector to be attached to the
node housing.
1
node housing.
1
Check the length and condition of the coaxial cable pin. The pin must be straight,
and the tip must be smooth with no burrs. The pin must measure 1.5 to 1.6
inches long (3.8 to 4.1 mm) from the tip to the base of the connector threads at the
o-ring location. Use the cutting length guide on the housing base for reference, as
shown below.
and the tip must be smooth with no burrs. The pin must measure 1.5 to 1.6
inches long (3.8 to 4.1 mm) from the tip to the base of the connector threads at the
o-ring location. Use the cutting length guide on the housing base for reference, as
shown below.
Important: The pin must meet the minimum length specified so the tip will
engage the seizure inside the housing before the connector threads engage the
housing. The pin must not exceed the maximum length in order to maintain
proper product performance.
If necessary, trim the pin using heavy-duty wire cutters, and then file the tip
smooth.
Note: Centering the pin length at 1.55 inches (3.95 mm) may make connector
installation easier. A common approach is to cut the pin 1/16 inch (1.6 mm)
longer than the cut guide on the housing.