Opening and Closing the Housing 
 
OL-29938-01 
45 
 
To Close the Housing 
Complete the following steps to close the DSAN 8211 housing. 
 
CAUTION: 
Avoid moisture damage and RF leakage! Follow the procedure exactly as 
shown below to ensure a proper seal.
 
1  Make sure that the housing gaskets are clean and in the correct position. Wipe off 
any excess dirt and debris. 
Close the housing. 
 
CAUTION: 
Ensure that all the cables are out of the way when closing the housing. 
3  Lightly secure the 8 half-inch closure bolts with a hex driver or ratchet. 
4  Using a torque wrench, tighten the closure bolts to 25 in-lb (2.8 Nm). 
Important: Tighten the closure bolts in the correct sequence as specified in 
Torque Sequence (on page 45). 
5  Using the same pattern, tighten the housing closure bolts from 5 to 12 ft-lb (6.8 to 
16.3 Nm). 
 
Torque Sequence 
The following diagram shows the proper torquing sequence for closing the DSAN 
8211 housing. Use the torque settings provided in Torque Specifications (on page 
216, on page 41).