Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 180
Chapter 3    Balancing and Setup 
 
 
 
proceeding. 
2  Ensure that the design value reverse output equalizer and reverse pads are 
installed in the appropriate reverse slots in the amplifier. Refer to the following 
diagram. 
Note: Record the pad values for each input port for later use. 
 
3  Proceed to 
To Calculate the Proper RF Signal Level (on page 78). 
 
 
To Calculate the Proper RF Signal Level 
In order to calculate the correct RF signal level to inject, you must know the 
following. 
 
Design Reverse Port Input Level from the design print 
 
Total Injection Insertion Loss (20 dB) 
To calculate the correct signal level to inject, add the total injection insertion loss to 
the design port input level.   
Example 
 
Design amplifier reverse port input level = 19 dBmV 
 
Total injection insertion loss = 20 dB 
The design amplifier reverse port input level plus injection insertion loss equals 
correct RF signal level to inject. 
In the example shown above, 19 dBmV + 20 dB = 39 dBmV. Therefore, you would 
set the signal generator output for + 39 dBmV. 
Important:   
 
When using a CW signal generator, inject at least two carriers, one at the low end 
and one at the high end of the reverse bandpass. In a reverse system with a 5 
MHz to 40 MHz bandpass, the low frequency carrier should be in the 5 MHz to 
10 MHz range and the high frequency carrier should be in the 35 MHz to 40 
 
78 
OL-30326-02