Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 174
 
 
Troubleshooting 
 
Troubleshooting 
Equipment 
The following equipment may be necessary to perform some troubleshooting 
procedures. 
 
Fiber optic ferrule cleaner, part number 468517, to clean fiber optic connectors 
 
99% alcohol and lint free wipes to clean fiber connectors 
 
Optical power meter to measure light levels 
 
Proper fiber connector for optical power meter to make optical connections 
 
Digital voltmeter to measure voltages 
 
Spectrum analyzer or a field strength meter to measure RF levels 
 
Test probe, part number 501111, to access test points 
 
External test probe, part number 562580, to access external test points 
 
Transmitter Module Troubleshooting Chart 
Follow the steps in the table below to troubleshoot the transmitter module. 
Symptom 
Possible Cause 
Possible Solutions 
No optical signal output  Laser temperature could be 
too high or low. 
Allow up to one minute 
after power is ON for the 
temperature to stabilize. 
If still no output, contact the 
Technical Service Center for 
assistance. 
Laser could be faulty. 
Contact the Technical 
Service Center for 
assistance. 
Automatic power control 
circuit failure. 
Contact the Technical 
Service Center for 
assistance. 
 
Damaged fiber. 
Contact the Technical 
Service Center for 
assistance. 
 
 
OL-29644-03 