Chapter 3    Balancing and Setup 
 
 
 
To Replace the Pad on the New OIB 
To achieve better transponder signaling, the new OIB board is used in the node with 
a 75 ohm plug-in pad to segregate the DOCSIS transponder signal in one single 
reverse path. When the transponder is removed, the new OIB board can be 
configurable by replacing the 75 ohm pad with a 0 dB pad to return to dual reverse 
signal paths.   
Note: See the figure of the 75 ohm pad on this page to identify your OIB board 
versions. Ignore this section if the old OIB board is applied.   
Complete the following steps to configure the pad if you need to set the node 
configuration to dual. 
1  Open the housing. Refer to 
To Open the Node Housing (on page 15). 
2  Press the fiber tray release toward the node housing, and then lift the fiber tray 
roughly 90 degrees to its unstowed position. 
3  Locate the 75 ohm pad on the interface board beneath the fiber tray hinge. 
4  With one hand on either side of the fiber tray, carefully unplug the 75 ohm pad 
from the interface board. Avoid pinching or pulling any nearby optical fibers. 
5  Align the replacement 0 dB plug-in pad completely with its corresponding hole 
and install the pad. 
6  Return the fiber tray to its stowed position, ensuring that the fiber tray release 
locks the fiber tray in place. 
7  When finished working inside the node, close the housing. Refer to 
To Close the 
Node Housing (on page 15). 
 
 
 
64 
OL-29644-03