Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 182
Chapter 2    Installation and Configuration 
 
 
 
Installing and Removing the Status Monitor 
Transponder Module (Optional) 
To Install the Status Monitor Transponder Module 
Complete the following steps to install the status monitor module. 
1  Open the node housing. Refer to 
To Open the Node Housing (on page 17). 
2  Align the transponder module connectors with the connectors on the interface 
board. Use the tabs on the bottom of the transponder as a guide to position the 
transponder correctly onto the interface board. 
 
3  Secure the status monitor transponder by pushing down on the module until it 
clicks into place. 
4  Tighten the two module retaining screws on the transponder to 18 in-lb to 20 
in-lb (2.0 Nm to 2.3 Nm). 
Result: 
 
If the GainMaker Node is active, the green “Heart Beat” LED flickers to 
indicate that the unit is operating. 
 
If data packages are detected (e.g., to another transponder) the “Receive” 
LED flickers. 
5  Close the node housing. Refer to 
To Close the Node Housing (on page 17). 
 
To Remove the Status Monitor Transponder Module 
Complete the following steps to remove the status monitor module. 
 
44 
OL-30035-03