Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split 설치 가이드
Chapter 2 Installation and Configuration
Installing and Removing the Status Monitor
Transponder Module (Optional)
To Install the Status Monitor Transponder Module
Complete the following steps to install the status monitor module.
1 Open the node housing. Refer to
1 Open the node housing. Refer to
To Open the Node Housing (on page 17).
2 Align the transponder module connectors with the connectors on the interface
board. Use the tabs on the bottom of the transponder as a guide to position the
transponder correctly onto the interface board.
3 Secure the status monitor transponder by pushing down on the module until it
clicks into place.
4 Tighten the two module retaining screws on the transponder to 18 in-lb to 20
in-lb (2.0 Nm to 2.3 Nm).
Result:
Result:
If the GainMaker Node is active, the green “Heart Beat” LED flickers to
indicate that the unit is operating.
If data packages are detected (e.g., to another transponder) the “Receive”
LED flickers.
5 Close the node housing. Refer to
To Close the Node Housing (on page 17).
To Remove the Status Monitor Transponder Module
Complete the following steps to remove the status monitor module.
44