Chapter 3    Balancing and Setup 
 
 
 
To Align the AGC Module 
Complete the following steps to align the AGC module. 
1  Make sure that switch S1 is set to position 2. 
 
2  Insert the test probe into the -20 dB forward main output test point on the 
amplifier. 
 
3  Measure and note the RF output level at the AGC pilot frequency.   
Note: Remember to add 20 dB to compensate for the test point loss. 
4  Set switch S1 to position 3 for AGC operation. 
5  Adjust the AGC gain control potentiometer to match the level you measured in 
step 3. 
 