Forward Path Balancing for AGC Stations Using Thermal Setup Mode 
 
2  Consult the design print to find the proper output tilt. 
3  Measure the output signal levels at the frequencies you used in 
To Verify the 
Input Signal Level (on page 51). 
4  To determine the actual output tilt, calculate the difference (in dB) between the 
levels of the lowest and highest specified frequencies. 
5  Proceed to the next section, To Set the Output Tilt
 
To Set the Output Tilt 
Equalizers (EQs) are available in 1.5 dB increments. A 1.5 dB change in value 
changes the difference between low and high frequencies by approximately 1 dB. 
 
Increasing the equalizer value reduces the level at lower frequencies, relative to 
the level at 870 MHz/1 GHz. 
 
Decreasing the equalizer value increases the level at lower frequencies, relative to 
the level at 870 MHz/1 GHz. 
Complete the following steps to select the proper forward input equalizer value. 
1  Compare the calculated output tilt in step 4 of To Determine the Output Tilt 
with the design tilt (on the design print). 
2  Is the output tilt within ±0.5 dB of the design tilt? 
 
If the output tilt is within ±0.5 dB of the design tilt, proceed to the next 
section, To Set the Output Level
 
If the output tilt is more than design tilt, replace the forward input EQ with a 
lower value.   
 
If the output tilt is less than design tilt, replace the forward input EQ with a 
higher value.   
Important: The forward input equalizer is installed at the factory and should not 
be changed in the field. While it is a 1 GHz equalizer, it is appropriate for use in 
both 1 GHz and 870 MHz applications. 
 
OL-30035-03 