Cisco Model D-PCG1000 PowerKEY CAS Gateway

Page of 18
78-4043063-01 Rev B 
 
11 
 
 
Stopping the In-Band Carousels 
 
Stopping the In-Band Carousels 
1  On the DNCS Administrative Console, click the Application Interface Modules 
tab. 
2  Click BFS Admin. One of the following windows opens: 
 
If you are using an RNCS, the Site Selection window opens. Go to the next 
step. 
 
If you are not using an RNCS, the BFS Hosts window opens. Go to step 4. 
Select the DNCS site and click Select. The BFS Hosts window opens. 
4  Click the BFS Sources tab. 
5  Click the Source ID column heading to sort the IDs in reverse numerical order 
(largest on top). 
Select the first enabled in-band source in the list. 
7  Click Edit. The Edit BFS Source window opens. 
8  Under Data Pump, select the stop option. 
9  Click Save. The source carousel stops. 
10  Select the next enabled in-band source in the list. 
11  Repeat this procedure from step 7 for each enabled in-band source under this 
host. 
12  Are you using our RNCS solution? 
 
If yes, repeat this procedure for each RNCS you are converting from ASI to 
GigE BFS. 
 
If no, you are finished with this procedure.