Cisco Headend System Release 2.5 Installation Guide

Page of 280
5-34 
SR 2.5 and SR 3.5 Post Upgrade Procedures 
78-738190-01 Rev B 
Change the DNCS Data Pump Rates,
 Continued 
Pioneer Resident Application Data Carousel Rate Settings 
The following table contains the recommended data carousel rates for a system that 
uses the Pioneer resident application. 
 
 
Source 
ID 
 
Data Carousel 
 
Data Rate 
(Mbps) 
 
Block Size 
(Bytes) 
 
Indication 
Interval  (ms) 
 
Enabled
1
 
System Carousel 
0.01 
1024 
200 
√ 
Out-of-Band 
0.01 
1024 
200 
√ 
Inband 
1.00 
4000 
100 
√ 
CAM OOB 
0.01 
1024 
200 
√ 
CAM IB
2
 
See note 2 
4000 
100 
See note 2 
IPG OOB 
0.05 
1024 
200 
√ 
IPG IB 
0.50 
4000 
100 
√ 
PPV OOB 
0.01 
1024 
200 
√ 
PPV IB 
0.50 
4000 
100 
√ 
SAM OOB
3
 
See note 3 
1024 
200 
See note 3 
10 
IPG2 IB 
0.50 
4000 
100 
√ 
11 
POD OOB 
0.03 
1024 
200 
√ 
12 
IPG3 IB 
0.50 
4000 
100 
√ 
14 
IPG4 IB 
0.50 
4000 
100 
√ 
16 
IPG5 IB 
0.50 
4000 
100 
√ 
18 
IPG6 IB 
0.50 
4000 
100 
√ 
20 
IPG7 IB 
0.50 
4000 
100 
√ 
21 
MMM OOB 
0.05 
1024 
200 
√ 
22 
PPV2 IB 
0.50 
4000 
100 
√ 
199
4 
bootloader 
3.00 
4000 
100 
√ 
2500 
PDT OOB 
0.06 
1024 
200 
√ 
2501 
PDT Medium 
0.06 
1024 
200 
√ 
2502 
PDT Small 
0.01 
1024 
200 
√ 
2503 
PDT IB 
1.00 
4000 
100 
√ 
2510
5
 
PDT MOD OOB 
0.02 
1024 
200 
√ 
2511
5
 
PDT MOD IB 
0.50 
4000 
100 
√