Cisco Headend System Release 2.5 Installation Guide
5-34
SR 2.5 and SR 3.5 Post Upgrade Procedures
78-738190-01 Rev B
Change the DNCS Data Pump Rates,
Continued
Pioneer Resident Application Data Carousel Rate Settings
The following table contains the recommended data carousel rates for a system that
uses the Pioneer resident application.
Source
ID
Data Carousel
Data Rate
(Mbps)
Block Size
(Bytes)
Indication
Interval (ms)
Enabled
1
0
System Carousel
0.01
1024
200
√
1
Out-of-Band
0.01
1024
200
√
2
Inband
1.00
4000
100
√
3
CAM OOB
0.01
1024
200
√
4
CAM IB
2
See note 2
4000
100
See note 2
5
IPG OOB
0.05
1024
200
√
6
IPG IB
0.50
4000
100
√
7
PPV OOB
0.01
1024
200
√
8
PPV IB
0.50
4000
100
√
9
SAM OOB
3
See note 3
1024
200
See note 3
10
IPG2 IB
0.50
4000
100
√
11
POD OOB
0.03
1024
200
√
12
IPG3 IB
0.50
4000
100
√
14
IPG4 IB
0.50
4000
100
√
16
IPG5 IB
0.50
4000
100
√
18
IPG6 IB
0.50
4000
100
√
20
IPG7 IB
0.50
4000
100
√
21
MMM OOB
0.05
1024
200
√
22
PPV2 IB
0.50
4000
100
√
199
4
bootloader
3.00
4000
100
√
2500
PDT OOB
0.06
1024
200
√
2501
PDT Medium
0.06
1024
200
√
2502
PDT Small
0.01
1024
200
√
2503
PDT IB
1.00
4000
100
√
2510
5
PDT MOD OOB
0.02
1024
200
√
2511
5
PDT MOD IB
0.50
4000
100
√