Cisco Headend System Release 2.7

Page of 174
 
Chapter 3    Staging SSC DHCTs 
 
 
 
94 
736107 Rev D 
Verifying the Staging Process 
After the staging process is complete, use the following checklist to check each SSC 
DHCT and confirm that the staging process was correctly completed. 
1  Verify that the correct current time appears on the front panel LED (if equipped 
with front-panel alphanumeric LEDs). 
2  Verify that the SSC DHCT is receiving audio and video on the following 
channels: 
 
Digital channels 
 
Premium (copy-protected) channels (this determines whether the SSC DHCT 
and its paired CableCARD module have been bound) 
3  Verify that the IPG channel banner is available on the bottom of the screen. 
4  View the CableCARD diagnostic screens and verify that the 
ENTITLEMENT AGENTS / ISE[1] field displays 0x0000001
5  View the diagnostic screens and verify that the date in the SUB EXPIRES field is 
at least 30 days in the future. 
6  If you are staging field-return or RMA SSC DHCTs, use the Staging Toolkit to 
verify the following settings:  
 
The Boot Status Indicator displays 111
 
All personal settings have been cleared and current site defaults are set. 
 
There are no stranded IPPV events. 
Note: Refer to the Returning DHCTs and CableCARD Modules to Service 
chapter in the Explorer Digital Home Communications Terminal Staging Guide (part 
number 734375) for more information.