Chapter 1    Staging Preparation 
 
 
 
32 
736107 Rev D 
6  Are you using SR 4.2 or later? 
 
If yes, go to step 7. 
 
If no, follow the instructions in Configuring System Release 4.0 to Support the 
Copy Protection Man-Machine Interface Screen (part number 736123) on how to 
implement the changes in steps 7 through 10 of this procedure. Then, go to 
step 11. 
7  Click the CableCARD Data Summary link at the top of the page. The 
CableCARD Summary screen opens. 
8  Click MMI Screen Format. The Configure Copy Protection MMI Screen opens. 
Example: The following illustration is an example of a Configure Copy 
Protection MMI Screen from SR 4.2.1. Screens in previous System Releases might 
look different. 
 
9  Make sure that the Display MMI for bi-directional device is activated (that a 
checkmark displays in the box). 
10  Click in the Bidirectional timeout (decimal seconds) and enter a zero. 
11  Click Save
12  Click Exit All CableCARD Screens to close the CableCARD Data Summary 
screen. 
13  From the DNCS section of the DNCS Administrative Console Status window, 
click Control. The DNCS Control window opens. 
14  From the list of processes, select CCardServer
15  Click Process > Stop Process. A confirmation window opens.