Cisco Headend System Release 2.7

Page of 198
 
 
Set Up the BFS 
78-745238-01 Rev D 
15 
 
Add the Inband Carousel to the PAT Table 
Determining the Session Number 
1  
On the DNCS Administrative Console, click the DNCS tab. 
2  Click the Application Interface Modules tab. 
3  Click Source. The Source List window opens. 
 
4  Click the Source ID column header to sort the list of sources by source ID. 
5  Write down two unused source numbers greater than 200 in the following 
spaces. 
Services Portal Inband Source _______________ 
Services Portal Out-of-band Source _______________ 
Notes: 
 
You will use the inband source number as the session number for the inband 
carousel in this procedure.  
 
You will use both the inband source and the out-of-band source numbers 
later in this section. 
 
Our numbering convention uses even numbers for inband sources and odd 
numbers for out-of-band sources. 
 
We recommend that the inband and out-of-band source IDs are sequential if 
possible. For example, source ID 202 for inband and source ID 203 for out-of-
band. 
 
You must use numbers greater than 200. Source IDs 1 through 200 are 
reserved for system-built sources. 
6  Close the Source List window from the File menu.