Cisco Headend System Release 2.7 Design Guide

Page of 124
 
Chapter 2    Monitoring SDV Alarms 
 
 
 
40 
4002915 Rev B 
SDV Session Alarms 
SDV Server Trap 100 (64 Hex) 
Alarm Summary: 
SDV Session Bind Failure 
Description: 
This alarm occurs when the server fails to bind a program to a session on the edge 
device. 
Severity: 
Major 
Service Impact: 
When this alarm occurs, the SDV client is denied service because a new program 
could not be established on the edge device. 
Check and Correct: 
Possible Cause 
Check and Correct Instructions 
The edge device may be unreachable. 
Analyze the error code associated with 
the alarm and determine if the SDV 
Server Alarm ID 6 (6 Hex) also 
occurred. 
If SDV Server Alarm ID 6 has occurred, 
then refer to the Check and Correct 
procedures for SDV Server Trap 6  
(6 Hex)
 (on page 31). 
If the SDV Server Alarm ID 6 has not 
occurred, then proceed to the next 
possible cause. 
Check and verify the amount of 
bandwidth  allotted for the service 
groups. 
Edge device software error. 
Investigate the edge device alarms and try 
to assess the cause of the error.