Cisco Headend System Release 2.5 Release Notes

Page of 168
 
Chapter 3    System Release 2.5/3.5/4.0 SP3 Installation Procedures 
 
 
 
48 
4004148 Rev C 
8  Have you backed up the DNCS file systems and database? 
 
If yes, type y and then press Enter. The system displays configuration 
parameters on the screen. 
 
If no, type n and then press Enter
Note:  If you type n, the installation will terminate. Back up the file systems 
and database and then repeat this procedure from step 4. 
9  Follow these instructions regarding the configuration parameters that are 
displayed on the screen. 
a  Examine the configuration parameters and follow onscreen instructions to 
change any parameter that needs to be changed. 
b  Type and then press Enter when you are finished. The installation 
continues. 
10  Type mv /etc/rc2.d/s75cron  /etc/rc2.d/S75cron and then press Enter. The system 
renames the s75cron file back to S75cron. 
11  Type eject cdrom and then press Enter when the installation is complete. 
12  Check the log file for errors.  
Notes: 
 
The installation log file is in the /dvs directory of the DNCS. The name of the 
log file is install_SP.log
 
Call Cisco Services for assistance if the log file reveals errors. 
13  Choose one of the following options: 
 
If you did not install DST software on the Application Server at the same time 
you installed service pack and DST software on the DNCS, go to Install DST 
Patches on the Application Server
 (on page 49). 
 
If you chose to install the two sets of software in parallel, wait until the 
software finishes installing on the Application Server, and then go to Install 
Additional Software
 (on page 50).