Chapter 5  Maintenance 
 
 
 
140 
OL-29643-02 
 
 
CAUTION: 
Do not use cleaning fluids containing trichloroethylene, 
trichloroethane, acetone or petroleum-based cleaners on equipment. 
Failure to comply with this caution could harm equipment surfaces.
 
 
4  Clean electrical contacts with spray-type contact cleaner. 
5  Clean internal connectors and circuit boards with hand-controlled, dry-air jet. Do 
not use pressure exceeding 15 lb/in2 (1.05 kg/cm2, or 103.43 kPa). 
6  Clean interior surfaces with clean cheesecloth moistened with isopropyl alcohol 
or general-purpose detergent. 
7  Clean internal electrical contacts with clean cheesecloth moistened with 
spray-type contact cleaner. 
8  Dry interior with clean, dry cheesecloth.