Chapter 2    Installing the GoQAM 
 
 
 
26 
4004834 Rev D 
Installing the Modulator into a Rack 
 
 
CAUTION: 
Do not tangle or strain interconnecting cables. 
Use caution when installing wiring and racks to avoid obstruction of airflow 
into the side air vents of the GoQAM or out of the vent fans on the side of the 
GoQAM. 
IMPORTANT: You must use the supplied notched rack mounts to provide 
additional support and to allow correct air circulation through the unit. 
 
1  Install the rack mounts. 
Important: The supplied rack mounts (Cisco part numbers 734845 and 734846) 
must be used. When you use the supplied rack mounts, you can install these 
modulators above or below each other in the rack with no space required. These 
rack mounts provide additional support along with the following features: 
 
Attaches directly to the rack 
 
Allows you to slide modulators partially out of the rack for service 
 
Allows appropriate air circulation throughout the unit 
2  Place the modulator in the rack. 
3  Insert a mounting screw through each of the four-bezel mounting holes on the 
front panel of the GoQAM and then into the rack. 
 
4  Firmly tighten each mounting screw. 
5  Go to 
Connect Power Sources (on page 27).