This section lists the power, rack, and environmental conditions necessary for 
installation. 
 
Power Requirements Table 
The following table describes the power specifications for the GoQAM. 
Item 
Specification 
Supply Voltage 
 
90V to 130V AC @ 47 to 63 Hz (AC unit) 
 
180V to 264V AC @ 47 to 63 Hz (AC unit) 
 
–42V to –57V DC (DC unit) 
Fuses 
 
4.0 A SLO BLO 250V (AC unit) 
 
6.3 A SLO BLO 250V (DC unit) 
Line Frequency 
 
47 Hz to 63 Hz (AC unit only) 
Power Required 
 
RF GoQAM: 155 VA (typical) 
 
IF GoQAM: 85 VA (typical) 
Power Dissipated 
 
RF GoQAM: 151 Watts (typical) 
 
IF GoQAM: 81 VA (typical) 
In Rush Current 
 
35 amps maximum, Vin = 130V AC (AC unit) 
 
75 amps maximum, Vin = 264V AC (AC unit) 
 
15 amps maximum, Vin = -57V DC (DC unit)