Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 192
 
 
Reverse Path Setup Procedure 
 
65 
 
Reverse Path Setup Procedure 
Introduction 
This procedure describes how to perform the reverse path setup. Perform this 
procedure only if the 1.2 GHz SHO GS7000 Node has an active reverse path. 
 
Optical Transmitter Setup Procedure 
Perform the following steps to set up the proper level into the reverse path optical 
transmitters. 
1  Open the housing according to Opening and Closing the Housing (on page 68). 
2  Verify the level of the input reverse RF signals at the RF test points located near 
the main ports of the RF amp module. Nominal level is +17 dBmV per channel. 
Install the appropriate value input pad at the REV PORT IN PAD location to 
attenuate the signal to the desired level for the reverse path of the node. 
3  With the input to the node port set to 17 dBmV per channel, a 4 dB transmitter 
input attenuator pad should be installed on the optical interface board (just 
above the transmitter module) to achieve 13 dBmV level into the optical 
transmitter (-7 dBmV at the transmitter -20 dB test point). This RF input level 
into the high gain reverse transmitter will achieve an optical modulation index 
(OMI) of 10%. 
4  Repeat steps 2 and 3 for each RF port carrying a reverse path signal. 
5  Use an optical power meter to measure the transmitter optical output power. 
(1330 nm or 1550 nm) 
Note: If you are operating the reverse path in 4X1 mode, make sure the reverse 
switch control on the launch amplifier is set to 4X1 position and install 75ohm 
pad load at XMTR 2 location of the OIB.   
If you are operating the reverse path in 4X2 mode, make sure the reverse switch 
control on the launch amplifier is set to 4X2 position, remove 75ohm pad load at 
XMTR 2 location on the OIB. Perform step 2-5 above for port 1 & 2 XMTR-1 and 
port 4 & 5 for XMTR-2