Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 192
 
 
Forward Path Setup Procedure 
 
63 
 
 
6  Set the receiver module attenuator switch as follows: 
 
IF received optical power is... 
THEN set the attenuator 
switch to... 
Standard Receiver 
—2 to +2 dBm 
-8 dB 
-6 to -2 dBm 
0 dB 
Low Input Receiver 
-6 to -2 dBm 
-8 dB 
-8 to -6 dBm 
0 dB 
7  For standard input receiver, check the RF level at the -20 dB RF test point on each 
forward path receiver. Signal level should be +7 dBmV at the test point with 0 
dBm optical input power and 2.5% index modulation of the laser headend 
transmitter. (With optical receiver attenuator set to the -8 dB switch setting.) This 
represents an optical receiver output of +27 dBmV. For low input receiver follow 
the same process to check the RF level and refer the table below. 
 
For standard receiver  For low input receiver  Att/OMI 
Output level 
  27dBmV 
27dBmV 
8 dB/2.5% 
Input optical 
power 
  0dBm 
-4dBm 
8 dB/2.5% 
8  The next step depends on your RF output levels. 
IF your RF output ports will... 
and you have... 
THEN... 
all have equal output levels 
1X segmentation 
Go to step 9. 
be driven at different levels 
1X segmentation 
Go to step 10.