Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 110
 
Chapter 4    Using the Craft Port 
 
 
 
38 
4037424 Rev A 
Console Access 
Important: 
 
Console access is intended for use by factory trained technicians. It is not 
recommended for use by technicians in the field. 
 
By default, Telnet access to the Ethernet port is enabled and the CM interface is 
disabled. If the use of the CM interface is desired, the operator must first enable 
the interface by setting the telnetIpStackInterfaces OID to the appropriate value, 
as shown in TelnetIpStackInterfaces OID Values and Descriptions below. 
In addition, the default username and password may be altered if desired. 
OIDs for Usernames, Passwords, Telnet Access for Console Access 
The following table contains a list of the OIDs in the telnetMgmt MIB that are used 
to change the username or password for the interfaces, enable or disable the 
interfaces, and enable or disable Telnet server access. 
Parameter 
OID 
Default 
telnetIpStackInterfaces  1.3.6.1.4.1.4413.2.2.2.1.1.1.1.0 
0x40 (hex) 
(CM interface is disabled 
and the Ethernet port 
interface is enabled) 
telnetUserName 
1.3.6.1.4.1.4413.2.2.2.1.1.1.2.0 
cheetah 
telnetPassword 
1.3.6.1.4.1.4413.2.2.2.1.1.1.3.0 
cheetah 
telnetServerControl 
1.3.6.1.4.1.4413.2.2.2.1.1.1.4.0 
1 (enabled) 
TelnetIpStackInterfaces OID Values and Descriptions 
The following table contains a list of the values for the telnetIpStackInterfaces OID 
along with the definition of each value. 
Value 
Setting 
0xC0 
CM interface enabled and Craft port interface enabled 
0x80 
CM interface enabled and Craft port interface disabled 
0x40 
CM interface disabled and Craft port interface enabled 
0x00 
CM interface disabled and Craft port interface disabled