Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split インストールガイド
Chapter 4 Using the Craft Port
38
4037424 Rev A
Console Access
Important:
Console access is intended for use by factory trained technicians. It is not
recommended for use by technicians in the field.
recommended for use by technicians in the field.
By default, Telnet access to the Ethernet port is enabled and the CM interface is
disabled. If the use of the CM interface is desired, the operator must first enable
the interface by setting the telnetIpStackInterfaces OID to the appropriate value,
as shown in TelnetIpStackInterfaces OID Values and Descriptions below.
disabled. If the use of the CM interface is desired, the operator must first enable
the interface by setting the telnetIpStackInterfaces OID to the appropriate value,
as shown in TelnetIpStackInterfaces OID Values and Descriptions below.
In addition, the default username and password may be altered if desired.
OIDs for Usernames, Passwords, Telnet Access for Console Access
The following table contains a list of the OIDs in the telnetMgmt MIB that are used
to change the username or password for the interfaces, enable or disable the
interfaces, and enable or disable Telnet server access.
to change the username or password for the interfaces, enable or disable the
interfaces, and enable or disable Telnet server access.
Parameter
OID
Default
telnetIpStackInterfaces 1.3.6.1.4.1.4413.2.2.2.1.1.1.1.0
0x40 (hex)
(CM interface is disabled
and the Ethernet port
interface is enabled)
and the Ethernet port
interface is enabled)
telnetUserName
1.3.6.1.4.1.4413.2.2.2.1.1.1.2.0
cheetah
telnetPassword
1.3.6.1.4.1.4413.2.2.2.1.1.1.3.0
cheetah
telnetServerControl
1.3.6.1.4.1.4413.2.2.2.1.1.1.4.0
1 (enabled)
TelnetIpStackInterfaces OID Values and Descriptions
The following table contains a list of the values for the telnetIpStackInterfaces OID
along with the definition of each value.
along with the definition of each value.
Value
Setting
0xC0
CM interface enabled and Craft port interface enabled
0x80
CM interface enabled and Craft port interface disabled
0x40
CM interface disabled and Craft port interface enabled
0x00
CM interface disabled and Craft port interface disabled