Input Parameters 
Description 
Traceroute size 
Range is 0 to 1518. 0 is the standard size, resulting in packets 
of 40 bytes inclusive of all overhead. 
Port 
Port to use. Standard is 33434 as the initial port. 
 
Controlling the Traceroute Test 
The Traceroute Test is controlled by the following buttons. 
Button 
Description 
Start Test 
Starts the Traceroute test. Each of the values provided in the 
input fields is evaluated for validity. 
 
If the host name field is blank, the test will not proceed. 
(The exception is leaving it blank when a previous name 
had been entered. In that case that name will be used.) 
 
Range checking on the parameters. Any parameter out 
of range will be ignored, and the default value used. 
Any issues with the parameters will be displayed at the top 
of the results box. When the test is started, the web page will 
begin to automatically refresh. This message also appears, 
indicating the parameters actually in use: 
Traceroute in use from <source>; max TTL xxx; size yyy; 
port nnnnn
 
This message is also in the text box. 
Abort Test 
Stops any traceroute test currently in progress. 
Clear Results 
Clears the results window. 
 
Test Results 
Below the test control buttons is a text area that displays the results of the Traceroute 
test. Any issues with the parameters will be displayed at the top of the results box. 
During a test, the web page will automatically refresh to show the current results. 
This refresh stops once the test is completed. 
The results area permits the user to select results and copy them for pasting into 
another program. You access this feature using one of the standard web browser 
methods: 
 
Left-click the box and press Ctrl-A (select all) 
 
Right-clicking in the box and click Select all