5  Remove the existing Low Pass Filter Trim modules (4 places)  
 
6  Install the new split Low Pass Filter Trim modules.  
7  Replace the reverse amplifier cover. Use the 8 screws removed previously, 
and tighten at 11 – 14 in-lb (1.25 – 1.58 Nm). 
8  Turn the RF module over for access to top side.
 
9  Loosen the screw on top of the diplexer 4 places and remove diplex filters. 
There are two (2) “mirrored” (blue PCB material) and two (2) “non-
mirrored”  (green PCB material) diplex filters. 
 
 
10  Install the four (4) new diplex filters. “Mirrored diplexers” (blue PCB material) 
are installed near ports 4 and 5, “non-mirrored diplexers” (green PCB material) 
are installed near ports 1 and 2.   The diplexers have plastic guides which are 
keyed to aid in insertion. Tighten diplexer cover screws to 6 – 8 in-lb (0.68 – 0.9 
Nm) to secure metal diplexer cover. 
11  Using Needle Nose pliers extract the High Pass Filter Modules (4 places).