Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 76
 
 Local Control Module 
Configuration Procedure
4024769 Rev A 
21
 
Menu Item  Configuration Parameter  Description/Values 
7 Power 
Supplies 
PS1 24V 
PS1 8V 
PS1 5V 
PS1 -6V 
PS2 24V 
PS2 8V 
PS2 5V 
PS2 -6V 
LCM Temp 
 
Description:  Read-Only status indication.  
Indicates the output voltage levels of power 
supplies 1 and 2.  LCM Temp indicates the 
operating temperature of the local control 
module. 
 
Values:  #.# V (for voltage levels), °F (for 
module temperature) 
Product Info, RO 
LCM Up Time 
Time In Service 
HandHeld SW Ver 
HandHeld SW No. 
LCM SW Ver 
LCM SW No. 
LCM Model No. 
Alarm Details 
 
Description:  Read-Only status indication.  
Indicates various product properties such as up 
time, time in service, and software version 
numbers. 
 
Values:  Hours (up time), Days (time in service), 
nnnnnn (various alpha-numeric values for 
version/number) 
9 Copy 
Parameters 
From Product 
Setting 1 
Setting 2 
Setting 3 
Setting 4 
Setting 4 
Setting 6 
Setting 7 
Setting 8 
Setting 9 
 
Description:  Read/Write configuration 
parameter.  Store up to nine node configuration 
settings for copying to a LCM in another node. 
 
Values:  Used, Empty