 Local Control Module 
Configuration Procedure
4024769 Rev A 
23
 
Note:  Use a small diameter screwdriver, or other small round tool that fits the hole 
in the housing, to press the Auto-Setup button.  Do not press hard.  The button only 
depresses about 1/64 inch (0.4 mm).  You can feel the button depress, but likely not 
hear it in a noisy environment. 
Results:  When pressed, the Auto-Setup button performs the following actions: 
  
Checks for installed modules 
  
Resets Rx and Tx thresholds only  (These thresholds are for switching only and 
are distinctly different than the alarm thresholds found in the HMS MIBs.) 
  
Resets all reverse band 6 dB (wink) switches to "low" 
The Auto-Setup process typically takes less than one second (~50 ms). 
Note:  During the module check, the LCM micro-controller samples the inputs from 
the optical transmitters (up to 4), optical receivers (up to 4), power supplies (up to 2), 
and AC lines (up to 2), to determine which of these items are installed in the node. 
 
Configuring the LCM Using the Model 91200 Handheld Programming Terminal 
Complete the following steps to configure the LCM using the handheld terminal. 
1  Connect the Model 91200 Handheld Programming Terminal to the local control 
port on the LCM as shown in the following illustration.