SDV Server Trap 501 (1F5 Hex) 
Alarm Summary: 
SDV Forced Protection Switch Failure 
Description: 
This alarm occurs when the SDV server cannot perform a protection switch to its 
partner SDV server. 
Severity: 
Major 
Service Impact: 
This is a redundancy failure that impacts the ability to use an SDV server as a backup. 
Check and Correct: 
Possible Cause 
Check and Correct Instructions 
Communications problem. 
Investigate and troubleshoot all SDV System 
Communications alarms. 
Partner SDV server is down. 
Investigate all SDV server alarms 
and errors that may have 
occurred around the time of the 
SDV server failure, particularly 
SDV Server Process alarms prior 
to the time of the failure. 
Call Cisco Services immediately 
for further assistance.