Cisco Headend System Release 2.7 User Guide
Chapter 2 Monitoring SDV Alarms
40
4000308 Rev B
SDV Server Trap 501 (1F5 Hex)
Alarm Summary:
SDV Forced Protection Switch Failure
Description:
This alarm occurs when the SDV server cannot perform a protection switch to its
partner SDV server.
partner SDV server.
Severity:
Major
Service Impact:
This is a redundancy failure that impacts the ability to use an SDV server as a backup.
Check and Correct:
Possible Cause
Check and Correct Instructions
Communications problem.
Investigate and troubleshoot all SDV System
Communications alarms.
Communications alarms.
Partner SDV server is down.
1
Investigate all SDV server alarms
and errors that may have
occurred around the time of the
SDV server failure, particularly
SDV Server Process alarms prior
to the time of the failure.
and errors that may have
occurred around the time of the
SDV server failure, particularly
SDV Server Process alarms prior
to the time of the failure.
2
Call Cisco Services immediately
for further assistance.