Cisco Headend System Release 2.7 Installation Guide
Chapter 4 Setting Up CMTS or OIT Bridges
66
4017650 Rev C
Note: The values shown in this screen are our recommended values for Max
Data Rate. You can edit these values as your system requires.
Data Rate. You can edit these values as your system requires.
12 Configure the following items in the OIT Data Configuration area of the Set Up
OIT Screen window:
a In the PID column, click in the EMM field and type the hexadecimal PID
a In the PID column, click in the EMM field and type the hexadecimal PID
value for the PowerKEY EMM stream. Allowable values=0x20-0x25.
Note: This setting selects the PID that carries inband EMMs on the Direct ASI
feed from the DNCS. This must be a unique value.
feed from the DNCS. This must be a unique value.
b In the PID column click in the Fast Refresh EMM field and type the
hexadecimal PID value for the Fast Refresh EMM stream. Allowable
values=0x20-0x25.
values=0x20-0x25.
Note: This setting selects the PID that carries Fast Refresh EMMs on the
Direct ASI feed from the DNCS. This must be a unique value.
Direct ASI feed from the DNCS. This must be a unique value.
c In the PID column, click in the System Messages field and type the
hexadecimal PID value for the System Messages stream. Allowable
values=0x20-0x25.
values=0x20-0x25.
Note: This setting selects the PID that carries system messages and
information on the Direct ASI feed from the DNCS. This must be a unique
value.
information on the Direct ASI feed from the DNCS. This must be a unique
value.
d In the PID column, click in the CAT field and type the hexadecimal PID
value for the CAT stream. This value is always set to one (1).
e In the PID column, click in the Messaging field and type the hexadecimal
PID value for the Messaging stream. Allowable values=0x20-0x25.
f In the Dncs ASI Pid column, click in the EMM field and type the
hexadecimal PID value for the PowerKEY EMM stream.