Cisco Headend System Release 2.5 Installation Guide

Page of 252
 
Appendix D 
Update the DHCT OUI with the updateOUI Utility 
226 
4020695 Rev C 
 
 
Resetting the OUI by DHCT MAC Address 
Follow these instructions to reset the OUI for a specific DHCT. 
1  If necessary, open an xterm window on the DNCS. 
2  Type updateOUI  -r  [MAC address] and then press Enter
Example:  updateOUI  -r  00:01:A6:5B:EE:BC 
Result:  The system restores the identifier on the specified DHCT and displays a 
message similar to the following: 
AlertServer.210>> updateOUI -r  00:01:A6:5B:EE:BC 
------------------------------------------------------------------------------------------------------- 
Nov 28, 9:31:33 - updateOUI Started. 
updateOUI Options:  -r  (Reset  OUI=MAC). 
Update done for MAC=00:01:A6:5B:EE:BC only. 
------------------------------------------------------------------------------------------------------
 
 
Reset the Null OUI 
Introduction 
Prior to SR 1.5.1, system operators had been able to set to null in the database the 
OUI, model number, and revision number of DHCTs that had trouble signing on to 
the network. Then, when these DHCTs did eventually sign on successfully to the 
network, the sign-on process automatically replaced these null values with valid 
values. Beginning with SR 1.5.1, however, DHCTs need a valid OUI to sign on to the 
network; DHCTs with a null OUI are unable to sign on.  System operators can run 
the updateOUI utility with the -rz option to replace null OUIs in the database with 
the first three octets of the DHCT MAC address. These DHCTs will then be able to 
sign on to the network. 
Important: If your system uses version 3.1 or later of the PowerTV operating system, 
you must run the updateOUI utility in the forward direction after resetting the null 
OUI in order for the DHCTs to sign on to the network.  
 
When to Reset the Null OUI 
Reset the null OUI whenever more than a very small number of DHCTs have the 
null OUI. To determine how many DHCTs have the null OUI, run the updateOUI 
utility in information mode (-i option). If the number of DHCTs with the null OUI is 
more than a few dozen, consider resetting the null OUI on those DHCTs. The 
following procedure, Resetting the Null OUI, provides an example of resetting the 
null OUI.