Cisco Headend System Release 2.7 Installation Guide

Page of 188
 
Chapter 7    Provision DTACS 
 
 
 
84 
78-4036705-01 Rev D 
Field 
Description 
Packet ID (PID) 
(hex) 
A hexadecimal value inserted in the header of each Authorization 
Management Message (AMM). This value indicates that the 
message contains AMM data.  
Activation Timeout 
(hours) 
The DTACS periodically sends this value to DTAs within AMM 
messages. This is known as refreshing the timeout value.   
 
If a DTA receives timeout values within this specified time 
period (in hours), the DTA remains activated.   
 
If a DTA does not receive timeout values within this time 
period, the DTA is deactivated.  
 
Range of valid values is from 2 to 2880. 
Provider Phone 
Number 
The service provider phone number. This field provides a way to 
contact the headend operator.  
Note: You can use a maximum of 255 alphanumeric characters 
(excluding the ampersand) in this field. 
UTC Offset 
The time zone in which the DTA Control System is installed. This 
value must adhere to these formatting rules:   
Minutes are expressed in 15-minute increments (for example, 
00, 15, 30, 45). 
The range of valid values is –14:00 to 12:00. 
Values are formatted as [–]HH:MM, where: 
– 
[–] is optional and denotes time behind UTC 
– 
HH denotes hours - You must include both hour positions. 
If your offset is a single-digit hour (such as minus 7 hours), 
place a zero (0) before the single digit (-07:00). 
– 
MM denotes minutes - You must include both minute 
positions, even if both positions are zeros (00). 
The offset can be positive (ahead of UTC) or negative (behind 
UTC). 
Examples: 
 
An entry of -05:00 means that your time zone is 5 hours 
behind UTC. 
 
An entry of 02:00 means that your time zone is 2 hours ahead 
of UTC. 
Use Daylight 
Saving Time (DST) 
Lets you specify whether or not your site uses DST. 
 
Enabled (checked) indicates that the system uses DST. 
 
Disabled (unchecked) indicates that the system does not use 
DST.