Chapter 4    Analyze System Configuration with the Doctor Report 
 
 
 
54 
740020 Rev H  
 
 
BFS Session Status 
The data in the BFS Session Status field verifies the following conditions: 
 
All BFS sources have an active session 
 
All sessions have a defined source 
Important!  If a BFS source does not have an active session, or if all sessions do not 
have a defined source, you have to create them. Call Cisco Services if you need help 
in creating a session or a source. 
 
Miscellaneous BFS Check 
The data in the Miscellaneous BFS Check field verifies the following conditions: 
 
No more than one dataCarousel process is running for a given BFS source. 
 
All BFS source definitions are present and are not duplicated. 
Note:  If a BFS source definition is not present, the source definition will not be in 
SI and the DHCT will be unable to tune to that carousel. 
 
No BFS source is encrypted. 
Important!  Note these important points about errors in the Miscellaneous BFS 
Check field: 
 
Refer to Recommendations for Data Carousel Rate Management Technical Bulletin, or 
your appropriate upgrade installation instructions for assistance in setting data 
rates. 
 
Passport sites, or sites running interactive applications (VOD, games, etc.) may 
generate data rate errors. Refer to one of the previously mentioned documents 
for assistance in setting data rates. 
Note: The dataCarousel processes are referred to as dataPump processes in SR 1.4 
and later. 
 
IPG Collector Report 
The data in the IPG Collector Report field reports on the success or failure of the last 
running of the IPG Collector process. 
Important!  If your data reveals that the IPG Collector failed to run, verify that you 
can log on to the site of your content provider. You may have network issues that 
prevent the IPG Collector from running.