Cisco Headend System Release 2.7 Installation Guide

Page of 92
 
Chapter 2    Installing the Alarm Manager Software 
 
 
 
38 
78-745262-01Rev C
 
5  Does the output from the command you executed in step 4 include any open 
user interface processes? 
 
If yes, follow these instructions. 
a  Determine whether the open user interface processes can be terminated. 
Someone may be accessing the DNCS from a remote connection and 
should not have their work interrupted. 
b  If you determine that the user interface process should be terminated, as 
root user type kill  [process ID] and then press Enter
Note:  Substitute the process ID of the user interface for [process ID]. 
Result:  The system terminates the process. 
c  Repeat steps 4 and 5. 
 
If no, go to step 6. 
6  Type  .  /dvs/dncs/bin/dncsSetup and then press Enter. This command 
establishes the DNCS environment as a root user. 
Important:  Type the period followed by a space before typing /dvs. 
Note:  The message -o: bad options may appear. This message is normal and 
does not affect the installation. 
7  Insert the Alarm Manager CD into the CD-ROM drive of the DNCS. The system 
automatically mounts the CD to /cdrom/cdrom0. 
8  Type df  -n and then press Enter. A list of the mounted filesystems appears. 
Note:  The presence of /cdrom in the output confirms that the system correctly 
mounted the CD. 
9  Type cd  /cdrom/cdrom0 and then press Enter. The /cdrom/cdrom0 directory 
becomes the working directory. 
10  Type ls  -la and then press Enter to generate a list of the files on the CD. 
Note:  The "l" is this command is a lowercase L. 
11  Type ./install_pkg and then press Enter. The system displays a copyright 
message and prompts the operator to press Enter to continue. 
12  Press Enter
Result:  One of the following results occurs: 
 
If Spectrum is installed on your system, the system displays a bold message 
that seeks permission to disable Spectrum. 
Note:  Spectrum and Alarm Manager cannot run simultaneously. 
 
If Spectrum is not installed on your system, the system displays the following 
message: 
Enter the hostname or the IP address of the DNCS interface physically 
connected to the Alarm Manager server.