Cisco Headend System Release 2.7 Installation Guide

Page of 158
 
Chapter 2    SR 5.0 Pre-Upgrade Procedures 
 
 
 
28 
4035749 Rev B 
Mount the DVD 
Depending upon your current Solaris patch set, the DVD may not mount 
automatically. Use the following chart to determine what method to use to mount 
the DVD. 
DNCS Release  SAIpatch Set 
DVD Mount Method 
SR 4.2 
4.2.1.6 and older  Manually mount 
SR 4.2 
4.2.1.10 
Automount 
SR 4.3 
4.3.0.1 
Manually mount 
SR 5.0 
10.20100322.2 
Automount 
Use the appropriate DVD mounting method for your current installation. 
Important:   
 
If you only have one DVD, you will need to complete this procedure each time 
you move the DVD from one system to another.  
 
To unmount a DVD, type cd / and then type 
umount /cdrom/cdrom
Note:  You should have an SR 5.0 DVD for each server that you are upgrading. 
Repeat this procedure for each DNCS and RNCS server that you are upgrading. 
Automount the DVD 
Follow these steps to automount the DVD. 
1  Inspect the DVD to ensure that it is clean. There should be no smudges on the 
DVD. Some small, light scratches may be present; this is fine.  
2  Insert the system release installation DVD into the CD-ROM drive of the server. 
Did the DVD automount? 
 
If yes, continue with the next procedure in this chapter. 
 
If no, as root user, type the following command and press Enter to restart the 
volfs process. 
svcadm restart volfs
 
Note:  If the DVD still does not automount, contact Cisco Support for 
assistance.