Cisco Prisma II bdr Dig Rev 2 1 Dual Mux Sys for High Density Installations Installation Guide

Page of 113
3-16 
Operation Using the ICIM 
78-715193-01 Rev C 
Monitoring Operating Status Using the ICIM 
Monitored Parameters  
You can monitor the status of operating parameters. The table below describes the 
monitored parameters for this module. 
Parameter  
Units 
Function 
+1_8VInt 
1.8 voltage level internal to the receiver. 
+3_3VInt 
3.3 voltage level internal to the receiver. 
ProcTemp 
°
Module temperature. 
ActivRcv 
1 or 2 
Which receiver sub-module is in use. 
RF_OUT_A 
RF_OUT_B 
On  
Off 
Indicates whether the actual output of RF 
channels A and B are On or Off. 
Rcv1Inst 
Rcv2Inst 
Inst 
Indicates if receiver sub-module is installed. 
Rcv1Type 
Rcv2Type 
1 or 2 
Indicates what type receiver sub-module is 
installed. 
1 = standard range receiver - PIN 
2 = extended range receiver - APD 
FramErrs 
Count 
The number of frame alignment word errors. 
RednMode 
Yes or No 
Indicates the redundancy mode for a second 
receiver in the same processor.  If Yes, the 
receiver acts as a backup to the primary 
receiver.  If No, redundancy is off. 
RFA_Attn 
RFB_Attn 
dB 
Indicates amount of attenuation has been 
configured for the RF outputs of each channel. 
ExtRedn 
Yes or No 
External Redundancy Mode.  If Yes, this 
processor acts as a backup to another 
processor until an external line indicates the 
primary processor has failed.  If No, external 
redundancy is off. 
Switch  
Deflt_1  
Deflt_2  
Force_1 
Force_2  
Deflt_1 or Deflt_2 describes default receiver.  
Force_1 or Force_2 forces switch to either 
receiver 1 or receiver 2. 
RF_Out_A 
RF_Out_B 
Auto, On or 
Off 
Indicates how the RF outputs are actually 
configured.  If On, the output is not muted.  If 
Off, the output is configured to be mute. If 
Auto, the processor has muted the output.