Operation Using the ICIM
78-715193-01 Rev C
Monitoring Operating Status Using the ICIM
Monitored Parameters
You can monitor the status of operating parameters. The table below describes the
monitored parameters for this module.
Parameter
Units
Function
+1_8VInt
V
1.8 voltage level internal to the receiver.
+3_3VInt
V
3.3 voltage level internal to the receiver.
ProcTemp
°
C
Module temperature.
ActivRcv
1 or 2
Which receiver sub-module is in use.
RF_OUT_A
RF_OUT_B
On
Off
Indicates whether the actual output of RF
channels A and B are On or Off.
Rcv1Inst
Rcv2Inst
Inst
Indicates if receiver sub-module is installed.
Rcv1Type
Rcv2Type
1 or 2
Indicates what type receiver sub-module is
installed.
1 = standard range receiver - PIN
2 = extended range receiver - APD
FramErrs
Count
The number of frame alignment word errors.
RednMode
Yes or No
Indicates the redundancy mode for a second
receiver in the same processor. If Yes, the
receiver acts as a backup to the primary
receiver. If No, redundancy is off.
RFA_Attn
RFB_Attn
dB
Indicates amount of attenuation has been
configured for the RF outputs of each channel.
ExtRedn
Yes or No
External Redundancy Mode. If Yes, this
processor acts as a backup to another
processor until an external line indicates the
primary processor has failed. If No, external
redundancy is off.
Switch
Deflt_1
Deflt_2
Force_1
Force_1
Force_2
Deflt_1 or Deflt_2 describes default receiver.
Force_1 or Force_2 forces switch to either
receiver 1 or receiver 2.
RF_Out_A
RF_Out_B
Auto, On or
Off
Indicates how the RF outputs are actually
configured. If On, the output is not muted. If
Off, the output is configured to be mute. If
Auto, the processor has muted the output.