Cisco Prisma II bdr Dig Rev 2 1 Dual Mux Sys for High Density Installations Installation Guide
78-715193-01 Rev C
Operation Using the ICIM
3-23
Checking bdr Receive Processor Alarms Using the ICIM,
Continued
Alarm Data Display
The alarm data for this module is shown below.
Alarm
Alarm Condition
Indication Possible Cause
Rcv1Pres
Receiver sub-module
1 not present
Fault
Receiver 1 not present.
Rcv2Pres
Receiver sub-module
2 not present
Fault
Receiver 2 not present.
Rcv1_LOS
Receiver sub-module
1 loss of signal
Fault
Check fiber line and data into
receiver sub-module 1.
Rcv2_LOS
Receiver sub-module
2 loss of signal
Fault
Check fiber line and data into
receiver sub-module 2.
Framing
The signal cannot be
framed
Fault
Check fiber connection path
and bdr transmitter.
Power_In
Power supply
indicates a fault
Fault
Check power cord. Make
sure power supply is fully
seated.
+1_8VInt
Internal 1.8 Voltage
Fault
Check power supply
module(s).
+3_3VInt
Internal 3.3 Voltage
Fault
Check power supply
module(s).
ProcTemp
Module Temperature Fault
Check fan tray operation.
FPGA
FPGA operation
Fault
Indicates the internal FPGA
has stopped working. Unit
needs repair.
OSM_Comm Cannot communicate
with the optical
receiver sub-module
Fault
Cannot communicate with the
receiver. Reseat or replace the
receiver sub-module.
APDBias1
APD1 bias incorrect
Fault
Re-seat receiver sub-module
1. Replace if necessary.
APDBias2
APD2 bias incorrect
Fault
Re-seat receiver sub-module
2. Replace if necessary.
Clock100
Internal clock
generator
Fault
Unit needs repair.