Alarm Data Display 
The alarm data for this module is shown below.   
Alarm  
Alarm Condition 
Indication  Possible Cause 
Rcv1Pres 
Receiver sub-module 
1 not present  
Fault 
Receiver 1 not present.  
Rcv2Pres 
Receiver sub-module 
2 not present  
Fault 
Receiver 2 not present.  
Rcv1_LOS 
Receiver sub-module 
1 loss of signal 
Fault 
Check fiber line and data into 
receiver sub-module 1. 
Rcv2_LOS 
Receiver sub-module 
2 loss of signal 
Fault 
Check fiber line and data into 
receiver sub-module 2. 
Framing 
The signal cannot be 
framed 
Fault 
Check fiber connection path 
and bdr transmitter. 
Power_In 
Power supply 
indicates a fault 
Fault 
Check power cord.  Make 
sure power supply is fully 
seated. 
+1_8VInt 
Internal 1.8 Voltage 
Fault 
Check power supply 
module(s). 
+3_3VInt 
Internal 3.3 Voltage 
Fault 
Check power supply 
module(s). 
ProcTemp 
Module Temperature  Fault 
Check fan tray operation. 
FPGA 
FPGA operation 
Fault 
Indicates the internal FPGA 
has stopped working.  Unit 
needs repair. 
OSM_Comm  Cannot communicate 
with the optical 
receiver sub-module 
Fault 
Cannot communicate with the 
receiver.  Reseat or replace the 
receiver sub-module. 
APDBias1 
APD1 bias incorrect 
Fault 
Re-seat receiver sub-module 
1. Replace if necessary. 
APDBias2 
APD2 bias incorrect 
Fault 
Re-seat receiver sub-module 
2. Replace if necessary. 
Clock100 
Internal clock 
generator 
Fault 
Unit needs repair.