Cisco Prisma II bdr Dig Rev 2 1 Dual Mux Sys for High Density Installations Installation Guide

Page of 113
3-24 
Operation Using the ICIM 
78-715193-01 Rev C 
Checking bdr Receive Processor Alarms Using the ICIM, 
Continued
 
User Alarm Thresholds 
User alarms are shown below. User alarms are not adjustable on this module. 
Alarm  
Function 
Major 
Low 
Thhold 
Minor 
Low 
Thhold 
Minor 
High 
Thhold 
Major 
High 
Thhold 
Unit 
Typical 
range 
+1_8VInt 
Internal 1.8 
voltage 
1.620 
1.67 
1.93 
1.980 
VDC 
1.77 – 
1.83 
+3_3VInt 
Internal 3.3 
voltage 
2.970 
3.070 
3.530 
3.630 
VDC 
3.2 – 3.4 
ProcTemp  Module 
temperature 
-40 
-10 
80 
85 
°
40-50 
 
Module Alarms 
Module alarms are shown below.   
Alarm  
Alarm Condition 
Indication 
Comments 
Rcv1Pres 
Receiver sub-module 1 
presence 
Fault 
Receiver sub-module 1 not 
present but should be. 
Rcv2Pres 
Receiver sub-module 2 
presence 
Fault 
Receiver sub-module 2 not 
present but should be. 
Rcv1_LOS  Receiver sub-module 1 
loss of signal 
Fault 
Check fiber line and data into 
receiver sub-module 1. 
Rcv2_LOS  Receiver sub-module 2  
loss of signal 
Fault 
Check fiber line and data into 
receiver sub-module 2. 
Framing 
Signal cannot be framed 
Fault 
Check fiber connection path 
and bdr transmitter.