Cisco Headend System Release 2.7 Installation Guide

Page of 32
 
Chapter 2    Activate SBE 
 
 
 
14 
740223 Rev F 
SBE Activation Day Two 
On Day Two you will verify that DIS is Enabled using the checkDIS.ksh utility to 
confirm all DHCTs are showing the DIS enable flag. Then you will check database 
counts to ensure the type 8 EMMs count is increasing. 
1  Are you logged into the DNCS as dncs user in the /dvs/dncs/bin directory?  
 
If yes, go to step 5. 
 
If no, go to step 2. 
2  Log on as dncs user. The password prompt appears. 
3  Type the dncs user password and press Enter
4  Type cd /dvs/dncs/bin and press Enter
5  Run the checkDIS.ksh command to see if any DHCTs have DIS disabled.   
Important: All DHCTs in your system should have DIS enabled. If you see any 
DHCTs with DIS disabled, then your billing system could be sending DIS 
disabled flags and you must contact the representative who handles your 
account. 
6  Run the checkDIS.ksh -c command to obtain two counts from the database. 
Note: It may take several minutes to receive count results. 
7  Record the database count results on a sheet of paper.  
Note: The desired result of these tasks is to have the two database counts match 
or for the first number to be larger than the second number by Day Five. You 
must contact the representative who handles your account if you do not notice 
progress from the last counts recorded on Day One. 
Important: Once you have completed this procedure, wait 3 days and then go to 
SBE Activation Day Five (on page 15).