Cisco Headend System Release 2.7 Installation Guide

Page of 32
 
 
SBE Activation Last Day (Seventeen) 
740223 Rev F 
19 
 
SBE Activation Last Day (Seventeen) 
Important: Ensure you have waited 7 full days since completing Day Ten activities 
before you begin Day Seventeen activities. 
On Day Seventeen complete the following steps to verify that DIS is enabled on your 
system DHCTs and check your system integrity to complete the SBE Setup Process. 
1  Are you logged into the DNCS as dncs user in the /dvs/dncs/bin directory? 
 
If yes, go to step 5.  
 
If no, go to step 2. 
2  Log on as the dncs user. The password prompt appears. 
3  Type the dncs user password and press Enter. 
4  Type cd /dvs/dncs/bin and press Enter. 
5  Run the checkDIS.ksh command to see if any DHCTs have DIS disabled:  
Important: All DHCTs in your system should have DIS enabled. If you see any 
DHCTs with DIS disabled, then your billing system may be sending DIS disabled 
flags. You must contact the representative who handles your account for 
assistance. 
6  Run the Doctor Report. In the report section titled Database Table Extents, check 
to see if the number of extents on the EMM table is increasing.  
Example: The following example shows typical Database Table Extents output. 
Database Table 
Extents 
atm_connection 
displaychannels 
elementary_stream 
elementtable 
elementtosource 
emm 
filemoduleinfo 
hct_profile 
Result: It is normal if the EMM extents are not listed, or if the number is 10 or 
less. If necessary, contact the representative who handles your account for 
assistance.