Cisco Headend System Release 2.5 Installation Guide

Page of 32
 
 
SBE Activation Last Day (Seventeen) 
740223 Rev F 
21 
 
The following image illustrates the VOD Information diagnostic screen.  
 
10  Open an xterm window on the DNCS. 
11  Type env | grep CUTOFF and press Enter to display the 
CAM_DIS_STAGING_CUTOFF_DATE. 
Note: Typically, the cutoff date expires after 20 days. This value is set during 
Day One activation tasks. 
12  When the CAM_DIS_STAGING_CUTOFF_DATE has expired, repeat step 9 to 
verify that the correct type 8 EMM count is still displayed for the newly staged 
DHCTs.  
Note: If the VOD cells field of the VOD Information diagnostic screen is showing 
00000000, then the DHCT has not received the type 8 EMMs needed for 
encryption. You must contact the representative who handles your account for 
assistance. 
13  You have finished the database and DHCT initialization. SBE preparation for 
your system is now complete.  
Important: If you have problems completing the initialization, contact the 
representative who handles your account.