Cisco Model D-PCG1000 PowerKEY CAS Gateway Maintenance Manual
Chapter 4 General Troubleshooting
30
4019476 Rev B
For GQAMs, the modeltype is 3
For RF GoQAMs, the modeltype is 4
For IF GoQAMs, the modeltype is 5
4 Type % and press Enter. A result similar to the following output, appears.
5 Type more [name of QAM]data and press Enter. A result, similar to the
following output, appears.
6 Did more than one config file appear?
If yes, keep the xterm window open and go to step 7.
If no, go to Checking the Software Version Associated with the config File
(on page 31).
(on page 31).
7 Do you need to continue to run different versions of software on some QAMs in
your network?
If yes, refer to the instructions contained in the software installation
instructions for your version of QAM code.
instructions for your version of QAM code.
If no, go to step 8.
8 Update the QAMs to use the same config file by performing the following steps:
a From the DNCS Administrative Console, click the DNCS tab, and then select
one of the following tabs:
–
For SR 2.7/3.7/4.2 and later, click Network Element Provisioning.
–
For SR 2.5/3.5/4.0 and earlier, click Element Provisioning.
b Click QAM. The QAM List window opens.
c Select the QAM device, click File and select Open. The Set Up [Name of
c Select the QAM device, click File and select Open. The Set Up [Name of
QAM] window opens.
d Click Advanced Parameters and modify the configuration file, as needed.
9 Go to Checking the Software Version Associated with the config File (on page
31).