Cisco Headend System Release 2.5 Installation Guide

Page of 102
 
 
Upgrade the RNCS Software 
78-4021167-01 Rev D 
47 
 
Upgrade the RNCS Software 
Upgrade the server with RNCS software using Solaris’ Live Upgrade. Live Upgrade 
is a Solaris facility that allows operating system or application upgrades in an 
inactive boot environment while the active boot environment continues to run 
without interruption. Therefore, do not shut down the ISDS, RNCS, or Application 
Server processes unless you are instructed to do so. 
Important: If you are installing RNCS software on a Sun Fire server for the first time, 
go to Initial Installation of RNCS Software (on page 1). 
 
RNCS Server Connection Options 
There are two options for connecting to the RNCS for software upgrades: 
 
Connect directly to the serial management port on the RNCS server with a 
laptop computer 
 
Remotely connect to the ALOM/ILOM network management port on the RNCS 
server  
Both options are covered in detail in the following sections. 
Connect Directly to the Serial Management Port on the RNCS Server with a 
Laptop Computer 
1  Connect a laptop computer to the serial management port of the RNCS server. 
2  Start the HyperTerminal application on the laptop and configure the application 
with the following parameters: 
Note:  The HyperTerminal application allows one computer to communicate 
with another computer. 
 
Baud rate — 9600 
 
Data bits — 8 
 
Parity — none 
 
Stop bit —  1 
 
Flow control — no 
3  Choose one of the following options: 
 
If you are connecting to a Sun Fire V245 server, press Enter and go to step 4. 
 
If you are connecting to a Netra T5220 server, press Enter and go to step 7.