Cisco Headend System Release 2.7 User Guide

Page of 282
 
 
 
Understand the Data in the Doctor Report Fields 
 
4031374 Rev B 
35 
 
generate data rate errors. Refer to one of the previously mentioned documents 
for assistance in setting data rates. 
Note: The dataCarousel processes are referred to as dataPump processes in SR 1.4 
and later. 
 
IPG Collector Report 
The data in the IPG Collector Report field reports on the success or failure of the last 
running of the IPG Collector process. 
Important:  If your data reveals that the IPG Collector failed to run, verify that you 
can log on to the site of your content provider. You may have network issues that 
prevent the IPG Collector from running. 
 
IPG Data Files 
The data in the IPG Data Files field verifies that the number of days of IPG data files 
on the system matches the number specified in the ipgcollectconfig table in the 
database. Additionally, the data in the IPG Data Files field reports the size of the IPG 
data files. 
Rovi Note:   Ignore errors at sites that run the Rovi resident application. 
Important:  Note these important points about errors in the IPG Data Files field: 
 
You may not have your IPG services mapped correctly. 
 
Your content provider may not be providing you with data for the channels you 
need. 
 
The content provider may be posting files after your IPG Collector runs. You 
may need to reschedule the time you run the IPG Collector. 
 
If IPG data files are smaller than expected, your IPG provider probably did not 
create or post your files correctly. Contact your IPG provider. 
 
Finally, run the ipgCollector manually. Then, use the appControl utility to stop 
and restart the ipgServer process on the Application Server. 
Note:  IPG data files typically are large files (100 KB). Small files are therefore 
flagged as errors.