Cisco Headend Digital Broadband Delivery System User Guide

Page of 259
12-4 
Power On and Off Options 
4002178 Rev C 
Supply Power to the AC Outlet on the Set-Top,
 Continued 
Specifying When Power Is Supplied to the AC Outlet on the Set-Top  
To specify whether power is supplied to the AC convenience outlet on the rear panel 
of the set-top at all times or only when the set-top is powered on, complete the 
following steps. 
Note:  If you want to allow subscribers to select when power is supplied to the AC 
convenience outlet on the set-top, see Allowing Subscribers to Specify When 
Power Is Supplied to the AC Outlet on the Set-Top, earlier in this section. 
1. 
On the DNCS Administrative Console, select the Server Applications tab. 
2. 
Click DHCT Config
Result:  The DHCT Configure Prompt window opens. 
3. 
Select Global
Result:  The Set Up Global DHCT Configuration window opens. 
4. 
Select the General Settings tab. 
Result:  The General Settings tab appears the forefront. 
5. 
Make sure the option for AC Outlet Control is not selected.  
Result:  When this field is not selected, subscribers cannot specify when 
power is supplied to the AC outlet on the set-top. Instead, you select when 
power is supplied to the outlet for the subscribers. 
6. 
Select the Base Application tab to select when power is applied to the AC 
outlet on the set-top for all subscribers. 
Result:  The Base Application tab appears in the forefront. 
7. 
For the AC Outlet Control field, select one of the following options: 
• 
On means that the AC convenience outlet has power at all times. 
• 
Switched means that the AC convenience outlet only has power when the 
set-top is powered on. 
Important:  This field appears on this tab only if AC Outlet Control is 
disabled on the General Settings tab. 
8. 
Click Save
Result:  Power is supplied to the AC outlet as you specified in step 7. 
9. 
Click Cancel
Result:  The DHCT Configure prompt opens. 
10.  Click File and Close to close the DHCT Configure prompt.