Cisco Model D-PCG1000 PowerKEY CAS Gateway Maintenance Manual

Page of 72
 
 
 
GoQAM, GQAM, and MQAM Modulator Front Panel LCD Alarm Messages 
 
4019476 Rev C 
49 
 
 
RF Alarms 
 
 
LCD Display 
Severity 
Probable Cause 
Check and Correct 
RF (1-4) 
Comm Failure 
Major 
Digital I/O board is not 
communicating with the 
modulator RF board MCU at the 
specified RF OUT module (1-4). 
This problem could be caused by 
a loose or broken cable or by the 
modulator MCU not being 
programmed correctly 
Reset the QAM device 
Contact Cisco Services 
 
RF (1-4) DC 
Lock detect 
error 
See also RF 
(1-4) UC Lock 
detect error 
Major 
 
Downconverter (DC) lock 
detect signal not functioning 
correctly. During Modulator 
MCU Power On Self Test 
(POST), the lock detect signal 
from the downconverter 
phase-locked loop (PLL) did 
not indicate an unlocked 
condition when one existed 
Note: Since the MCU cannot 
correctly detect locked or 
unlocked status, the RF 
Output field displays 
“MUTED” when this condition 
occurred 
 
The output converter 
synthesizer lock detect 
circuitry has malfunctioned 
Contact Cisco Services 
RF (1-4) DC 
PLL unlocked 
Major 
Downconverter (DC) PLL 
synthesizer cannot lock. The 
output frequency may not be 
correct. The RF Output field 
displays “MUTED” when this 
condition exists 
Contact Cisco Services 
RF (1-4) 
EEPROM 
failure 
Minor 
Modulator EEPROM failure. The 
EEPROM on the modulator board 
is not present or is not 
operational. If this alarm is set, 
RF calibration data is not 
available and the “RF (1-4) Level 
not calibrated” alarm is also active 
Contact Cisco Services